24VDC UPS with integrated Li-Ion battery protects against plant downtime and data loss

Bicker Elektronik presents UPSI-2406DP1 with durable Li-Ion backup, bridging power failures, brownouts and flicker in 24VDC supply network. The DC UPS modules are approved to IEC/UL/CSA 61010-1 / -2-201 and ideal for long-term use in switch cabinets and decentralized self-sufficient solutions. The new intelligent UPSI-2406DP1 protects industrial and medical PCs, controls, motor drives, sensors, measurement devices, safety technology, etc.

Uninterruptible DC power supply
24V DC UPS with integrated Li-Ion battery protects against plant downtime and data loss caused by power failures

The reliable and fail-safe DC power supply of embedded IPCs, controls, motor drives, sensors, measurement devices and safety technology is of fundamental importance in networked high-tech systems worldwide and in almost all fields of application. Plant downtimes, system failures and loss of data can become risky and costly. By using intelligent DC UPS systems, this risk can be significantly minimized and the uninterruptible power supply and thus reliability is assured. For this purpose, the power supply specialist Bicker Elektronik, Donauwoerth / Germany, presents a particularly compact and durable solution with an excellent price-performance ratio: The new DC UPS module UPSI-2406DP1 with integrated Lithium-Ion backup battery, which bridges power failures, brownouts and flicker in the 24VDC power supply. Due to optimized power electronics, DC loads of up to 100 Watt can be safely bridged.

Maximum safety for 24VDC applications

The new 24VDC emergency power supply UPSI-2406DP1 in a robust DIN rail housing is ideally suited for long-term 24/7 continuous operation in switch cabinets and decentralized self-sufficient solutions for Industry 4.0, automation, robotics, image processing, medical and laboratory technology, transportation, process and safety technology, traffic monitoring, energy, communication, vending, payment systems / POS, and many more.

What are the advantages of Li-Ion technology over lead-acid batteries?

With regard to system integration and economy (TCO), energy storage devices with space and weight savings of up to 75% can be realized with Lithium-Ion cells compared to conventional lead-acid batteries. Lithium is the lightest metal in the periodic table and has ideal electrochemical properties for providing high specific energy densities (Wh/kg). Under comparable operating conditions the number of charging cycles (cycle life ≥500 for UPSI-2406DP1) and the achievable DoD (Depth of Discharge) are significantly higher than with lead-acid batteries and the service life of Li-Ion cells is even up to five times longer.

Reliable bridging of longer power failures

In normal operation, the system electronics of the UPSI-2406DP1 make the nominal mains input voltage available at the output, charge the Li-Ion battery pack and monitor the voltage thresholds at the input. If the voltage falls below the defined threshold, the system switches to UPS backup mode within fractions of a second and ensures an uninterrupted and regulated voltage supply for the connected 24V DC consumer at the output. With a capacity of 2.5 Ah / 37 Wh, the internal Lithium-Ion battery provides enough energy to bridge a load of 96 Watt for approx. 15 minutes or a load of 25 Watt for approx. 60 minutes.

‘Power sharing’ with intelligent input current detection

The intelligent distribution of the charging currents (PowerSharing) ensures that the upstream AC/DC power supply does not have to be oversized, but that the input power is kept constant and distributed accordingly to the load and Li-Ion battery charger. With a low load at the output, more energy flows into the charger and vice versa. Thus energy consumption, space requirements and costs can be reduced.

‘Smart Battery Lock’ prevents battery discharge
The battery management system prevents the integrated battery pack from leakage discharging when the UPSI-2406DP1 is switched off by deactivating the battery accordingly. By reducing the BMS own power consumption to a minimum, safety and shelf life of the DC UPS also increases significantly.

The integrated minimum load detection with the help of a load sensor at the output switches off the DC UPS when the threshold value is not reached (no load) so as not to use up energy unnecessarily. In addition, the UPSI-2406DP1 has overcurrent and reverse polarity protection as well as deep discharge protection.

Pre-programmable for self-sufficient operation

The management software HID Control Center – available for free download – is for setting and preprogramming various parameters of the DC UPS system as well as real-time monitoring with charge status display. The parameters that can be set include: Load sensor (mA), shutdown delay, maximum backup time, minimum load capacity before system start, ignition timer and restart delay. The data connection to the IPC system takes place via the integrated USB interface.

Shutdown & Reboot function for IPC systems

In the event of a “PowerFail”, the DC UPS signals the failure of supply voltage via integrated interface, so that a controlled shutdown of the computer system can be initiated and valuable data can be saved. The integrated reboot function of the DC-UPS automatically initiates the restart of the supplied IPC after the supply voltage has returned, without the need for costly on-site intervention by service staff, e.g. with completely self-sufficient computer systems at inaccessible locations.

Tested according to IEC/UL/CSA 61010-1 / -2-201

The DC UPS system UPSI-2406DP1 has international safety certifications for worldwide use: ETL UL61010-1 / -2-201, CSA C22.2 61010-1-12 / -2-201, CB Scheme IEC 61010-1 /-2-201.

Front interfaces and DIN rail mounting

All inputs and outputs are arranged on the front of the UPSI-2406DP1. In addition to the connections for input and output voltage with status LED, this includes a relay contact (PowerFail), an RS232 communication interface and a USB interface. The compact and high-quality aluminum housing (63 x 120 x 100 mm) is equipped with a DIN rail holder on the rear for flexible and quick top-hat rail mounting.

Comprehensive service & support

In addition to the three-year device warranty, Bicker Elektronik GmbH guarantees long-term availability of at least 5 years on the new DC UPS UPSI-2406DP1. In particular, applications with a correspondingly long runtime benefit from optimal investment protection with first-class design-in advice and extensive service & support from the specialists at Bicker Elektronik. On request, the development engineers at Bicker Elektronik can implement customer-specific and special solutions and also offer extensive laboratory and measurement services for complete customer systems.

Bicker UPSI-2406DP1

All features at a glance

  • 24V DC UPS module with integrated Li-Ion battery pack
  • Long-life Lithium-Ion cells
  • High energy density – long backup times
  • Intelligent input current detection
  • ‘Power sharing’ between charger and load
  • Regulated output voltage in backup mode
  • ‘Smart Battery Lock’ and minimum load detection
  • Relay contact for power fail
  • Power fail timer function
  • USB & RS232 interface
  • HID Control Center software included
  • Shutdown & Reboot function for IPC
  • Battery fuel gauge
  • Approved to IEC/UL/CSA 61010-1 / -2-201
  • Excellent price-performance ratio
  • 3 years warranty

Direct link to UPSI-2406DP1:

https://www.bicker.de/en/UPSI-2406DP1

Contact us for more information:
Bicker Elektronik GmbH
Ludwig-Auer-Straße 23
86609 Donauwörth

Telefon: +49 (0)906 70595-0
Telefax: +49 (0)906 70595-55

E-Mail: info@bicker.de
Internet: www.bicker.de

This slideshow requires JavaScript.

You may also like...